Why it happens
Air holds moisture. When warm air touches a surface colder than its dew point, the moisture condenses into water. In a metal building, the underside of the roof cools quickly at night, and moisture from people, animals, vehicles, concrete, heaters and the ground condenses on it. The water drips, stains, rusts framing and damages stored goods.
The fixes
1. Insulate with a vapor retarder. Metal building insulation with a facing on the warm (inside) side keeps moist air from reaching the cold metal. Seal facing seams and edges with tape so the retarder is continuous.
2. Ventilate. Moving air carries moisture out. Ridge vents, gable vents, wall louvers or exhaust fans help, especially in buildings with animals, vehicles or water.
3. Reduce moisture at the source.
- Put a vapor barrier under new concrete slabs.
- Slope the ground away from the building.
- Vent heaters that burn fuel; unvented heaters add a lot of moisture.
- Close up gaps where outside humid air comes in.
4. Consider other insulation types.
- Spray foam on the underside of the roof both insulates and seals.
- Reflective insulation with an air gap can help in hot climates, but needs sealed seams to control condensation.
- Anti-condensation backers on some panels (a fabric layer on the underside) absorb small amounts of moisture and let it evaporate. They help with light condensation in open buildings, but don't replace insulation in heated buildings.
Retrofitting an existing building
- Spray foam can be applied to the underside of existing panels.
- Insulation systems can be installed between purlins from inside.
- Adding ventilation and fixing moisture sources is the low-cost first step.